Blog Index
The journal that this archive was targeting has been deleted. Please update your configuration.
Navigation

Airblast and vibration data

The Dynamate has a 100% capture rate due to its histogram search facility alowing "after the event" searches and data capture.

Dynamates, continuously record (at either 500 or 1000 Hz), the air blast and vibration signals in an endless sample buffer loop. This recording continues independently of any other software process. At the maximum sample rate, the buffer stores up to 10 days of air blast and vibration data.

When triggered from a blast event, the central Dynamaster software generates an event file containing event summary information and the event data sets and will automatically upload the event file.

The sample buffer contents can also be explored by the user. Users can issue a trigger an event file to be generated and uploaded to the central server. This facility is useful for determining background signal levels, or to capture blast event data in cases where a trigger has not been successfully generated. For example, when a shot is fired and vibration levels are insufficient to cause a threshold trigger.

Dust, blast emissions and visibility data

Ecotech's data management system (WinCollect) has advanced data logging and collection capabilities which allow instantaneous downloading of data from multiple sites/stations at once. WinCollect can be scheduled to automatically download data over user defined time period or alert environmental managers when a parameter exceeds the upper limit set by regulations.

WinCollect has flexibility in how it downloads data. WinCollect can download data over 3G/Next G networks, via modems, radio, satellites or through dial-up phone lines, ethernet networks and directly from Serial port (RS-232).